Update protocol.md (#436)
Adjust documentation on transmit format * Trailer is actually 0x00 0x0d 0x05 (ie the extended pulse length format) * Trailer doesn't have to be this value on transmit This is based on work in https://github.com/elupus/irgen, but is just a qualified guess that seem to match reality.
This commit is contained in:
parent
957baf5447
commit
bbab292bbe
@ -181,11 +181,13 @@ Send the following payload with a command byte of 0x006a
|
|||||||
|0x05|repeat count, (0 = no repeat, 1 send twice, .....)|
|
|0x05|repeat count, (0 = no repeat, 1 send twice, .....)|
|
||||||
|0x06-0x07|Length of the following data in little endian|
|
|0x06-0x07|Length of the following data in little endian|
|
||||||
|0x08 ....|Pulse lengths in 2^-15 s units (µs * 269 / 8192 works very well)|
|
|0x08 ....|Pulse lengths in 2^-15 s units (µs * 269 / 8192 works very well)|
|
||||||
|....|0x0d 0x05 at the end for IR only|
|
|....|For IR codes, the pulse lengths should be paired as ON, OFF|
|
||||||
|
|
||||||
Each value is represented by one byte. If the length exceeds one byte
|
Each value is represented by one byte. If the length exceeds one byte
|
||||||
then it is stored big endian with a leading 0.
|
then it is stored big endian with a leading 0.
|
||||||
|
|
||||||
|
Captures of IR codes from the device will always end with a constant OFF value of `0x00 0x0d 0x05` but the trailing silence can be anything on transmit. The likely reason for this value is a capped timeout value on detection. The value is about 102 milliseconds.
|
||||||
|
|
||||||
Example: The header for my Optoma projector is 8920 4450
|
Example: The header for my Optoma projector is 8920 4450
|
||||||
8920 * 269 / 8192 = 0x124
|
8920 * 269 / 8192 = 0x124
|
||||||
4450 * 269 / 8192 = 0x92
|