mirror of
https://github.com/mjg59/python-broadlink.git
synced 2024-06-02 22:00:14 +02:00
Fix bugs
This commit is contained in:
parent
f840d5d187
commit
fbc0f01994
|
@ -1,6 +1,5 @@
|
|||
"""Support for climate control."""
|
||||
import enum
|
||||
import logging
|
||||
import struct
|
||||
from typing import List, Sequence
|
||||
|
||||
|
@ -261,7 +260,7 @@ class hvac(Device):
|
|||
"""Controls a HVAC.
|
||||
|
||||
Supported models:
|
||||
- Tornado SMART X SQ series.
|
||||
- Tornado SMART X SQ series
|
||||
- Aux ASW-H12U3/JIR1DI-US
|
||||
- Aux ASW-H36U2/LFR1DI-US
|
||||
"""
|
||||
|
@ -317,7 +316,7 @@ class hvac(Device):
|
|||
def _encode(self, data: bytes) -> bytes:
|
||||
"""Encode data for transport."""
|
||||
packet = bytearray(10)
|
||||
p_len = 8 + len(data)
|
||||
p_len = 10 + len(data)
|
||||
struct.pack_into(
|
||||
"<HHHHH", packet, 0, p_len, 0x00BB, 0x8006, 0, len(data)
|
||||
)
|
||||
|
@ -346,8 +345,8 @@ class hvac(Device):
|
|||
|
||||
def _send(self, command: int, data: bytes = b"") -> bytes:
|
||||
"""Send a command to the unit."""
|
||||
command = bytes([((command << 4) | 1), 1])
|
||||
packet = self._encode(command + data)
|
||||
prefix = bytes([((command << 4) | 1), 1])
|
||||
packet = self._encode(prefix + data)
|
||||
response = self.send_packet(0x6A, packet)
|
||||
e.check_error(response[0x22:0x24])
|
||||
return self._decode(response)[0x02:]
|
||||
|
@ -365,6 +364,7 @@ class hvac(Device):
|
|||
swing_h (hvac.SwHoriz):
|
||||
swing_v (hvac.SwVert):
|
||||
sleep (bool):
|
||||
ifeel (bool):
|
||||
display (bool):
|
||||
health (bool):
|
||||
clean (bool):
|
||||
|
@ -372,11 +372,15 @@ class hvac(Device):
|
|||
"""
|
||||
resp = self._send(1)
|
||||
|
||||
if len(resp) != 0x0F:
|
||||
raise ValueError(f"unexpected resp size: {len(resp)}")
|
||||
if len(resp) < 13:
|
||||
raise e.DataValidationError(
|
||||
-4007,
|
||||
"Received data packet length error",
|
||||
f"Expected at least 15 bytes and received {len(resp) + 2}",
|
||||
)
|
||||
|
||||
state = {}
|
||||
state["power"] = resp[0x08] & 1 << 5
|
||||
state["power"] = bool(resp[0x08] & 1 << 5)
|
||||
state["target_temp"] = 8 + (resp[0x00] >> 3) + (resp[0x04] >> 7) * 0.5
|
||||
state["swing_v"] = self.SwVert(resp[0x00] & 0b111)
|
||||
state["swing_h"] = self.SwHoriz(resp[0x01] >> 5)
|
||||
|
@ -384,6 +388,7 @@ class hvac(Device):
|
|||
state["speed"] = self.Speed(resp[0x03] >> 5)
|
||||
state["preset"] = self.Preset(resp[0x04] >> 6)
|
||||
state["sleep"] = bool(resp[0x05] & 1 << 2)
|
||||
state["ifeel"] = bool(resp[0x05] & 1 << 3)
|
||||
state["health"] = bool(resp[0x08] & 1 << 1)
|
||||
state["clean"] = bool(resp[0x08] & 1 << 2)
|
||||
state["display"] = bool(resp[0x0A] & 1 << 4)
|
||||
|
@ -400,8 +405,13 @@ class hvac(Device):
|
|||
ambient_temp (float): ambient temperature
|
||||
"""
|
||||
resp = self._send(2)
|
||||
if len(resp) != 0x18:
|
||||
raise ValueError(f"unexpected resp size: {len(resp)}")
|
||||
|
||||
if len(resp) < 22:
|
||||
raise e.DataValidationError(
|
||||
-4007,
|
||||
"Received data packet length error",
|
||||
f"Expected at least 24 bytes and received {len(resp) + 2}",
|
||||
)
|
||||
|
||||
ac_info = {}
|
||||
ac_info["power"] = resp[0x1] & 1
|
||||
|
@ -416,26 +426,25 @@ class hvac(Device):
|
|||
self,
|
||||
power: bool,
|
||||
target_temp: float, # 16<=target_temp<=32
|
||||
mode: int, # hvac.Mode
|
||||
speed: int, # hvac.Speed
|
||||
preset: int, # hvac.Preset
|
||||
swing_h: int, # hvac.SwHoriz
|
||||
swing_v: int, # hvac.SwVert
|
||||
mode: Mode,
|
||||
speed: Speed,
|
||||
preset: Preset,
|
||||
swing_h: SwHoriz,
|
||||
swing_v: SwVert,
|
||||
sleep: bool,
|
||||
ifeel: bool,
|
||||
display: bool,
|
||||
health: bool,
|
||||
clean: bool,
|
||||
mildew: bool,
|
||||
) -> None:
|
||||
"""Set the state of the device."""
|
||||
# TODO: What does these values represent?
|
||||
# TODO: decode unknown bits
|
||||
UNK0 = 0b100
|
||||
UNK1 = 0b1101
|
||||
UNK2 = 0b101
|
||||
|
||||
target_temp = round(target_temp * 2) / 2
|
||||
if not 16 <= target_temp <= 32:
|
||||
raise ValueError(f"target_temp out of range: {target_temp}")
|
||||
|
||||
if preset == self.Preset.MUTE:
|
||||
if mode != self.Mode.FAN:
|
||||
|
@ -453,7 +462,7 @@ class hvac(Device):
|
|||
data[0x02] = ((target_temp % 1 == 0.5) << 7) | UNK1
|
||||
data[0x03] = speed << 5
|
||||
data[0x04] = preset << 6
|
||||
data[0x05] = mode << 5 | (sleep << 2)
|
||||
data[0x05] = mode << 5 | sleep << 2 | ifeel << 3
|
||||
data[0x08] = power << 5 | clean << 2 | (health and 0b11)
|
||||
data[0x0A] = display << 4 | mildew << 3
|
||||
data[0x0C] = UNK2
|
||||
|
|
Loading…
Reference in New Issue