lordneon
90af3b7437
Fixed a bug within the SP2 class.
...
check_power and check_nightlight did not check to see if the payload was already an int before calling ord.
2018-04-15 10:19:05 +00:00
Daniel Høyer Iversen
3b6b55ae73
Merge pull request #164 from horse315/master
...
fixed Hysen thermostat ctor & added comments
2018-03-31 15:57:17 +02:00
Daniel Høyer Iversen
e9f4bb6372
Merge pull request #169 from ooo89/master
...
Add support for Clas Ohlsson OEM branded SP3
2018-03-31 15:56:06 +02:00
ooo89
832a40c278
Update __init__.py
2018-03-28 16:56:36 +02:00
Aleksey Bogomolov
e9748ff0b4
fixed Hysen thermostat ctor & added comments
2018-03-24 19:05:44 +03:00
Daniel Høyer Iversen
ed6cec9b7f
Merge pull request #161 from mikalstill/patches
...
Add the RM3 mini to the supported device list.
2018-03-24 14:47:44 +01:00
Michael Still
53b213ea85
Add the RM3 mini to the supported device list.
...
I picked one of these up cheap on ebay and it totally works.
2018-03-19 18:19:51 +11:00
Matthew Garrett
9286d9a1d9
Version 0.8
2018-03-18 15:12:47 -07:00
clach04
8b593beff9
Restore Python 3 support ( #95 )
...
Use explicit byte literals.
AES encryption padding broken with commit f7e30344c5
under Python 3.
Python 3 support when using pyaes (instead of Crypto.Cipher.AES) now works.
2018-03-18 15:12:20 -07:00
Matthew Garrett
8d3c9f1e9f
Version 0.7
2018-03-18 15:08:21 -07:00
Nightreaver
33a2e4ae54
implemented method to toggle nightlight on some SP3 devices ( #159 )
...
* implemented method to toggle nightlight on some SP3 devices
* implement nightlight feature to cli
* check_power/check_nightligh fixes for py2.7
2018-03-18 15:03:46 -07:00
Peter Windridge
39cc64efce
Basic support for Hysen Heating Controller (dev type 0x4ead) ( #138 )
...
* Initial support for Hysen heating controller device. Only gets current temperature.
* Add switch_to_auto() to put the controller in (pre-programmed) timed mode
* Add set_temp() to manually set temperature. Now requires PyCRC (payload needs modbus CRC16)
* Remove test script
* Get current timer schedule
* Get much more data from device
* Add PyCRC to install_requires setup.py
* Rewrite based on better understanding. Allow setting schedule and changing 'loop mode'
* Add set_time function
* Support advanced settings and perform CRC check on responses
* Explain remaining unknowns for Hyson thermostat
The room_temp_adj (or simply 'adj') only applies to the room_temp. It's limited to -5.0..+5.0, but uses a 2 byte data type.
This leads to the assumption that external_temp could also use this data type, maybe for showing temperatures below 0 - but I cannot test this currently. Maybe I have to place it near a fridge to confirm.
* Fix get_temp and add get_external_temp for Hysen
Again: maybe payload[17] also belongs to the external temperature...
* remove comment about first 2 bytes and raise error if CRC check on response fails
* Remove comment about guessed meaning of unknown
Just confirmed, that lowest outside temp is 0. So it seems to only need 1 byte, as room temp does.
* add ability to toogle hysen device power
Turn display power on/off
* Update set_power() to support remote_lock for Hysen
Sorry, there was still one thing missing: set/unset remote_lock.
I captured again and changed the set_power accordingly.
* fix comments
2018-03-18 15:03:26 -07:00
Nightreaver
8754493951
broadlink_discovery returns wrong devtype ( #157 )
...
* few item in gendevice use `if` instead of `elif`
* passing `devtype` back to device
change `cli/broadlink_discovery` to display proper devtype
2018-03-18 14:58:15 -07:00
Marcin Koperski
21d96bd140
Add option to switch state ( #160 )
...
Find lacking for an option in one line to switch a state of SP2 switches
2018-03-18 14:55:03 -07:00
marconfus
26109aac67
Fix for environments where Crypto and pyaes are installed. ( #151 )
...
If both Crypto and pyaes are installed 'pyaes' is in sys.modules(), but as it is not imported (see top) it's not available.
Fix for #128
2018-03-18 14:54:17 -07:00
Daniel Høyer Iversen
00cc79daee
Merge pull request #149 from deel77/master
...
Default support for python3 in get_energy() for SP2
2018-03-10 15:30:42 +01:00
Daniel Høyer Iversen
0742039477
Merge pull request #156 from Nightreaver/master
...
add new rmpro models
2018-03-10 15:30:10 +01:00
Daniel Høyer Iversen
e8795ac1ae
Merge pull request #150 from balloob/patch-1
...
Depend on pycryptodome instead of pycrypto
2018-03-10 15:29:33 +01:00
Steven Barthen
d186332b96
add new rmpro models - Pro Plus 3, Pro Plus 300, Pro Plus HYC, Pro Plus R1, Pro PP
2018-03-10 21:10:33 +09:00
Paulus Schoutsen
38aa6dc37e
Depend on pycryptodome instead of pycrypto
2018-02-27 00:26:07 -08:00
Dominik Lakatoš
51ff890c7c
modified get_energy() to support python3
2018-02-08 13:47:28 +01:00
Brent Avery
4e33ef4465
Get rf scan learning working in CLI tool ( #87 )
2018-01-30 07:50:51 +11:00
Valter Vicente
dd0e908317
New flags: check power state and turn device on & off ( #132 )
...
Added new flags so it is possible to check device's current power state and to turn device on & off from CLI
2017-12-25 00:35:09 +00:00
Aleksandr Smirnov
82172f54ab
support for dooya curtain motor ( #134 )
2017-12-25 00:34:37 +00:00
Sergey Bogatyrets
9ff6fa817b
Checking device arg too for defining dev instance ( #129 )
2017-11-26 11:10:19 -08:00
Matthew Garrett
dd6eb8767e
Experimental RF code
2017-11-25 12:38:57 -08:00
Matthew Garrett
8bc67af6d7
Bump version
2017-11-25 12:21:48 -08:00
jazzina
b8cf8d073e
Add support for SmartOne Alarm Kit
2017-11-25 12:20:46 -08:00
blapid
c85f6ac213
Cli venv support ( #127 )
...
* Update broadlink_cli
* Update broadlink_discovery
2017-11-25 12:14:34 -08:00
Michael Kaiser
71f320638e
Fix protocol description ( #125 )
...
* Fix discovery packet format description
* fix MAC address offset
* Command packet format description
* Data description
2017-11-25 12:14:12 -08:00
Eugene Schava
2160488da2
sp2.get_energy
2017-11-25 12:11:05 -08:00
Eugene Schava
626b459b5b
SP3S support ( #117 )
2017-11-25 12:08:58 -08:00
hackers365
1d7fba3d06
add honyar mp1 devtype 0x4ef7
2017-11-25 12:08:14 -08:00
Bengt Martensson
4f902342e7
New options for broadlink:cli: --convert and --durations. ( #105 )
...
Now takes several data arguments.
2017-11-25 12:06:12 -08:00
Julian Pastarmov
3d4789305e
Only get temperature for devices that support it. ( #102 )
...
Calling check_temperature is only possible on the RM family of devices. The program used to crash if other types of devices were discovered (A1, MP1 etc.).
2017-11-25 12:04:10 -08:00
mob41
2e2c8ef1a1
[Critical] Fixes invalid byte string (b) for padding ( #97 , #107 ) ( #108 )
...
* Fixes invalid byte string (b) for padding (#97 , #107 )
* Change version to 0.5
2017-06-13 19:30:27 -07:00
kost
f7e30344c5
pad the payload for AES encryption (16) ( #92 )
2017-05-07 11:32:52 -07:00
Daniel Høyer Iversen
f1d62380c9
Merge pull request #86 from RobSullivan/master
...
Python3.5 syntax changes
2017-04-26 11:09:57 +02:00
Robert Sullivan
babb3f83d3
Python3.5 syntax changes
2017-04-25 15:33:00 +01:00
Aydaen Lynch
d989c27d36
Add in AP Mode device setup for new Broadlink devices. ( #53 )
2017-04-22 12:48:02 -07:00
Ivan Martinez
5195856200
included sensors option
2017-04-22 12:42:32 -07:00
Ivan F. Martinez
de7c5c2a2a
basic documentation for cli programs
2017-04-22 12:42:32 -07:00
Ivan Martinez
76dd4cfc70
command line programs to control broadlink devices
2017-04-22 12:42:32 -07:00
tobiaswaldvogel
846cc35366
More details about the data structure for IR and RF pulses ( #58 )
...
* Added more details to payload structure
2017-04-22 12:41:30 -07:00
wind-rider
3c44422b60
Update protocol.md
2017-04-22 12:40:04 -07:00
wind-rider
2388808f41
Add device type mapping to protocol
2017-04-22 12:40:04 -07:00
Daniel Høyer Iversen
19851ed423
bug fix in timeout ( #70 )
2017-04-22 12:38:02 -07:00
Dimitrij
d346476e63
fix check_power for SP2/SP3 ( #72 )
...
Fixed up to avoid merge conflict with #78
2017-04-22 12:36:50 -07:00
Thomas Järvstrand
4f03ffb963
Add support for pure python AES implementation ( #78 )
2017-04-22 12:34:37 -07:00
Matthew Garrett
7a852b2084
Bump version to 0.3
2017-01-03 10:08:06 -06:00